Create and Configure the vFC Interfaces for the Compute Hosts

From this point on, <<san_a_mac_address>> refers to the MAC address for SAN_A, and
<<san_b_mac_address>> refers to the MAC address for SAN_B.
Create and Configure the vFC Interfaces for the Compute Hosts
Procedure
1 Log in to <<net_switch1_mgmt_ip>> through SSH.
2 Run the system-view command to enter system-view mode.
3 From system-view, create the vFC for the LOM 1 port of the first management server and associate it with
FCoE VSAN A.
Note
You can use any vFC identifier you wish in the range of 1 to 1024. The vFC IDs shown in the example
code are the ones used in the verified configuration.
interface vfc 1
description <<enclosure_1_blade_bay_1_hostname>>-LOM1
port trunk vsan <<net_fcoe_vsan_a_id>>
bind interface Bridge-Aggregation 111 mac <<san_a_mac_address>>
quit
4 Create the vFC for the LOM 2 port of the first management server and associate it with FCoE VSAN B.
interface vfc 201
description <<enclosure_1_blade_bay_1_hostname-LOM2
port trunk vsan <<net_fcoe_vsan_b_id>>
bind interface Bridge-Aggregation 112 mac <<san_b_mac_address>>
quit
©