Create the Zone Definitions for the Nimble Storage Array to the
Management Systems
Create the Zone Definitions for the Nimble Storage Array to the Management Systems
After the aliases for the Nimble Storage array and management server ports are created, the zones must be
created.
Procedure
1 The first zone will be from <<mgmt_server_1_hostname>>-LOM1 to <<nimble_system_name>>.
2 Enter system-view and run the vsan <<net_fcoe_vsan_a_id>> command.
system-view
vsan <<net_fcoe_vsan_a_id>>
3 Create the zone for vsan a.
zone name <<mgmt_server_1_hostname>>-LOM1-to-<<nimble_system_name>>
member zone-alias <<mgmt_server_1_hostname>>-LOM1
member zone-alias <<nimble_system_name>>-CA-fc5
member zone-alias <<nimble_system_name>>-CA-fc9
member zone-alias <<nimble_system_name>>-CB-fc5
member zone-alias <<nimble_system_name>>-CB-fc9
quit
4 Enter system-view and run the vsan <<net_fcoe_vsan_b_id>> command.
system-view
vsan <<net_fcoe_vsan_b_id>>
5 Create the zone for vsan b.
zone name <<mgmt_server_1_hostname>>-LOM2-to-<<nimble_system_name>>
member zone-alias <<mgmt_server_1_hostname>>-LOM2
member zone-alias <<nimble_system_name>>-CA-fc6
member zone-alias <<nimble_system_name>>-CA-fc10
member zone-alias <<nimble_system_name>>-CB-fc6
member zone-alias <<nimble_system_name>>-CB-fc10
quit
6 Repeat these steps to create zones for the second management server.
7 Save the configuration.
Create and Activate the Zone Set
Using the newly created zones, create the zone set and activate it.
Procedure
1 Enter system-view and run the vsan <<net_fcoe_vsan_a_id>> command.
system-view
vsan <<net_fcoe_vsan_a_id>>
2 Create zone set san-a and add the appropriate zones.
zoneset name san-a
member <<mgmt_server_1_hostname>>-LOM1-to-<<nimble_system_name>>
member <<mgmt_server_2_hostname>>-LOM1-to-<<nimble_system_name>>
quit
©
Copyright
2017 by Nimble Storage, Inc. All rights reserved.
Documentation Feedback
64