Convert Interfaces To Use Fc Protocol; Add Individual Port Descriptions For Troubleshooting - HP Converged Architecture 700 Deployment Manual

With nimble storage
Table of Contents

Advertisement

Convert Interfaces to Use FC Protocol

vlan <<vm_production_net_1_vlan>>
name VM-Production-VLAN1
quit
vlan <<fcoe_san_a_vlan>>
name FCoE-SAN-A-VLAN
description FCOE SAN A (VSAN <<net_fcoe_vsan_a_id>>)
quit
vlan <<fcoe_san_b_vlan>>
name FCoE-SAN-B-VLAN
description FCOE SAN B (VSAN <<net_fcoe_vsan_b_id>>)
quit
save
Convert Interfaces to Use FC Protocol
Convert the needed ports to serve as Fibre Channel (FC) ports.
Procedure
1 From system-view, run the following command:
interface range Ten-GigabitEthernet 1/2/1 to Ten-GigabitEthernet 1/2/6
Ten-GigabitEthernet 2/2/1 to Ten-GigabitEthernet 2/2/6
port-type fc

Add Individual Port Descriptions for Troubleshooting

Add individual port descriptions for troubleshooting activity and verification. The following examples use a
single Nimble Storage array with dual controllers.
Procedure
1 From system-view, run the following commands:
interface FortyGigE 1/1/1
description <<enclosure_1_name>>-VC1:Q1
quit
interface FortyGigE 1/1/2
description <<enclosure_1_name>>-VC1:Q2
quit
interface FortyGigE 2/1/1
description <<enclosure_1_name>>-VC2:Q1
quit
interface FortyGigE 2/1/2
description <<enclosure_1_name>>-VC2:Q2
quit
interface FortyGigE 1/1/7
description Switch1-IRF-Switch2-IRF-2/1/7
quit
interface FortyGigE 1/1/8
©
Copyright
2017 by Nimble Storage, Inc. All rights reserved.
Documentation Feedback
31

Advertisement

Table of Contents
loading

Table of Contents