Parameter

01.057 Force Reference Direction

Short description
Defines the direction of the reference
Mode
Open‑loop
Minimum
0
Default
0
Type
8 Bit Volatile
Display Format
Standard
Coding
RW, TE
Value
Text
0
None
1
For
2
Rev
If Force Reference Direction (01.057) = 0 then it has no effect. If Force Reference Direction (01.057) is non-zero then the modulus of the reference is used and
the sign is defined by the value of Force Reference Direction (01.057). If Force Reference Direction (01.057) = 1 then Pre-skip Filter Reference (01.002) is
always positive, and if Force Reference Direction (01.057) = 2 then Pre-skip Filter Reference (01.002) is always zero or negative.
Parameter

01.069 Reference in rpm

Short description
Displays the value of the reference in rpm
Mode
Open‑loop
Minimum
-33000
Default
Type
32 Bit Volatile
Display Format
Standard
Coding
RO, ND, NC, PT
Reference in rpm (01.069) = Pre-ramp Reference (01.003) x 60 / Pole Pairs (see Number Of Motor Poles (05.011)).
Parameter

01.070 Clamped Reference

Short description
Displays the reference that is provided for the PID controller
Mode
Open‑loop
Minimum
−VM_SPEED_FREQ_REF
Default
Type
32 Bit Volatile
Display Format
Standard
Coding
RO, VM, ND, NC, PT
The Clamped Reference (01.070) is provided as a source for various drive user functions.
Parameter
01.071 Alternative Reference
Short description
Defines the reference which is used as a destination for the output of the PID controller
Mode
Open‑loop
Minimum
−VM_SPEED_FREQ_REF
Default
0.00
Type
32 Bit Volatile
Display Format
Standard
Coding
RO, VM, NC
Alternative Reference (01.071) is provided as a destination for an alternative reference if required (such as a drive user function output).
If Alternative Reference (01.071) has been programmed as a destination, Alternative Reference Enable (01.072) is set to 1 automatically so that the alternative
reference is selected.
Parameter
01.072 Alternative Reference Enable
Short description
Indicates when the Alternative Reference is being used
Mode
Open‑loop
Minimum
0
Default
Type
1 Bit Volatile
Display Format
Standard
Coding
RO, ND, NC, PT
See Alternative Reference (01.071).
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
Maximum
2
Units
Update Rate
4ms read
Decimal Places
0
Maximum
33000
Units
rpm
Update Rate
4ms write
Decimal Places
0
Maximum
VM_SPEED_FREQ_REF
Units
Hz
Update Rate
4ms write
Decimal Places
2
Maximum
VM_SPEED_FREQ_REF
Units
Hz
Update Rate
4ms read
Decimal Places
2
Maximum
1
Units
Update Rate
4ms read
Decimal Places
0
27