Negative Reference Clamp Enable; Reference Offset Select; Bipolar Reference Enable; Reference On/Reverse Select/Jog Select - Emerson Unidrive M200 Parameter Reference Manual

Open-loop mode
Hide thumbs Also See for Unidrive M200:
Table of Contents

Advertisement

Parameter

01.008 Negative Reference Clamp Enable

Short description
Set to 1 to allow the minimum reference clamp value to be negative
Mode
Open‑loop
Minimum
0
Default
0
Type
1 Bit User Save
Display Format
Standard
Coding
RW
See Minimum Speed (01.007).
Parameter

01.009 Reference Offset Select

Short description
Enables the use of the reference offset
Mode
Open‑loop
Minimum
0
Default
0
Type
8 Bit User Save
Display Format
Standard
Coding
RW
See Reference Offset (01.004).
Parameter

01.010 Bipolar Reference Enable

Short description
Enables the minimum value of the reference to be negative
Mode
Open‑loop
Minimum
0
Default
0
Type
1 Bit User Save
Display Format
Standard
Coding
RW
See Minimum Speed (01.007).
Parameter
01.011 Reference On
Short description
Indicates that the reference from the reference system is active
Mode
Open‑loop
Minimum
0
Default
Type
1 Bit Volatile
Display Format
Standard
Coding
RO, ND, NC, PT
Reference On (01.011), which is controlled by the drive sequencer (see Menu 06) indicates that the reference from the reference system is active. Note that
Reference On (01.011) is also used to enable and disable the Hard Frequency Reference (03.022).
Parameter
01.012 Reverse Select
Short description
Indicates when the reverse function is active
Mode
Open‑loop
Minimum
0
Default
Type
1 Bit Volatile
Display Format
Standard
Coding
RO, ND, NC, PT
Reverse Select (01.012), which is controlled by the drive sequencer (see Menu 06), is used to invert Reference Selected (01.001) or the Jog Reference (01.005).
Parameter
01.013 Jog Select
Short description
Indicates when the jog function is active
Mode
Open‑loop
Minimum
0
Default
Type
1 Bit Volatile
Display Format
Standard
Coding
RO, ND, NC, PT
Jog Select (01.013) which is controlled by the drive sequencer (see Menu 06), is used to select the Jog Reference (01.005).
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
Maximum
1
Units
Update Rate
Background read
Decimal Places
0
Maximum
2
Units
Update Rate
4ms read
Decimal Places
0
Maximum
1
Units
Update Rate
4ms read
Decimal Places
0
Maximum
1
Units
Update Rate
2ms write
Decimal Places
0
Maximum
1
Units
Update Rate
2ms write
Decimal Places
0
Maximum
1
Units
Update Rate
2ms write
Decimal Places
0
19