Logic Function 1 Source 1 Invert; Logic Function 1 Source 2; Logic Function 1 Source 2 Invert; Logic Function 1 Output Invert/Logic Function 1 Delay - Emerson Unidrive M200 Parameter Reference Manual

Open-loop mode
Hide thumbs Also See for Unidrive M200:
Table of Contents

Advertisement

Logic Function 1 Source 1 (09.004) defines input souce 1 of logic function 1.
Parameter

09.005 Logic Function 1 Source 1 Invert

Short description
Set to invert input 1 of logic function 1
Mode
Open‑loop
Minimum
0
Default
0
Type
1 Bit User Save
Display Format
Standard
Coding
RW
Setting Logic Function 1 Source 1 Invert (09.005) inverts input 1 of logic function 1.
Parameter

09.006 Logic Function 1 Source 2

Short description
Defines input source 2 of logic function 1
Mode
Open‑loop
Minimum
0.000
Default
0.000
Type
16 Bit User Save
Display Format
Standard
Coding
RW, PT, BU
Logic Function 1 Source 2 (09.006) defines input source 2 of logic function 1.
Parameter

09.007 Logic Function 1 Source 2 Invert

Short description
Set to invert input 2 of logic function 1
Mode
Open‑loop
Minimum
0
Default
0
Type
1 Bit User Save
Display Format
Standard
Coding
RW
Setting Logic Function 1 Source 2 Invert (09.007) inverts input 2 of logic function 1.
Parameter
09.008 Logic Function 1 Output Invert
Short description
Set to invert the ouptut of logic function 1
Mode
Open‑loop
Minimum
0
Default
0
Type
1 Bit User Save
Display Format
Standard
Coding
RW
Setting Logic Function 1 Output Invert (09.008) inverts the output of logic function 1.
Parameter
09.009 Logic Function 1 Delay
Short description
Defines the output delay of logic function 1
Mode
Open‑loop
Minimum
-25.0
Default
0.0
Type
16 Bit User Save
Display Format
Standard
Coding
RW
Logic Function 1 Delay (09.009) defines the delay at the output of logic function 1. If Logic Function 1 Delay (09.009) is positive then the output does not
become 1 until the input to the delay has been at 1 for the delay time. If Logic Function 1 Delay (09.009) is negative then the output remains at 1 until
the input to the delay has been 0 for the delay time.
130
Maximum
1
Units
Update Rate
4ms read
Decimal Places
0
Maximum
30.999
Units
Update Rate
Drive reset read
Decimal Places
3
Maximum
1
Units
Update Rate
4ms read
Decimal Places
0
Maximum
1
Units
Update Rate
4ms read
Decimal Places
0
Maximum
25.0
Units
s
Update Rate
4ms read
Decimal Places
1
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10