Emerson Unidrive M200 Parameter Reference Manual page 251

Open-loop mode
Hide thumbs Also See for Unidrive M200:
Table of Contents

Advertisement

Trip
dcct
Value
110
Short description
DC Current transformer failure (size 5 and above)
DCCT reference out of range (size 5 and above only).
Recommended actions:
Hardware fault - contact the supplier of the drive.
Trip
Der.E
Value
246
Short description
Derivative Image error
An error has been detected in the derivative product image. The sub-trip indicated the reason for the trip.
Sub-trip
Reason
1
The derivative image is missing or is invalid
The derivative image does not match the control board
2
hardware
The derivative image has been changed for an image
3
with a different derivative number.
Trip
Der.I
Value
248
Short description
Derivative program error
An error has been detected in the derivative product image. The sub-trip indicates the reason for the trip.
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
Comments
Occurs when the drive powers-up. Load valid derivative image
matching the control board hardware.
Occurs when the drive powers-up. Load valid derivative image
matching the control board hardware.
Occurs when the drive powers-up or the image is programmed.
The image tasks will not run.