Relay 1 Output State; Digital I/O 1 Invert; Digital I/O 2 Invert; Digital Input 3 Invert/Digital Input 4 Invert/Digital Input 5 Invert - Emerson Unidrive M200 Parameter Reference Manual

Open-loop mode
Hide thumbs Also See for Unidrive M200:
Table of Contents

Advertisement

Parameter

08.008 Relay 1 Output State

Short description
Displays the state for relay 1
Mode
Open‑loop
Minimum
0
Default
Type
1 Bit Volatile
Display Format
Standard
Coding
RO, ND, NC, PT
Relay 1 Output State (08.008) shows the state of Relay 1, 0 = Relay open, 1 = Relay closed.
Parameter

08.011 Digital I/O 1 Invert

Short description
Set to 1 to invert digital input/output 1
Mode
Open‑loop
Minimum
0
Default
0
Type
8 Bit User Save
Display Format
Standard
Coding
RW, TE
Value
Text
0
Not.Inv
1
Invert
A value of 0 or 1 in Digital I/O 1 Invert (08.011) allows the I/O state to be non-inverted(0) or inverted(1) respectively.
If Digital I/O 01 mode (08.031) = 0 (Input) then Digital I/O 1 Invert (08.011) inverts the destination parameter Digital IO1 Source/Destination A (08.021) or DI/O 01 Source/Destination B (08.121).
If Digital I/O 01 mode (08.031) = 1 (Output) then Digital I/O 1 Invert (08.011) inverts Digital I/O 1 State (08.001) and the voltage on the output terminal.
If Digital I/O 01 mode (08.031) = 2 or 3 (Frequency or PWM output) then Digital I/O 1 Invert (08.011) has no effect.
Parameter

08.012 Digital I/O 2 Invert

Short description
Set to 1 to invert digital input/output 2
Mode
Open‑loop
Minimum
0
Default
0
Type
8 Bit User Save
Display Format
Standard
Coding
RW, TE
Value
Text
0
Not.Inv
1
Invert
A value of 0 or 1 in Digital I/O 2 Invert (08.012) allows the input state to be non-inverted(0) or inverted(1) respectively.
Digital I/O 2 Invert (08.012) inverts the destination parameter Digital IO2 Source/Destination A (08.022) or DI/O 02 Source/Destination B (08.122).
Parameter
08.013 Digital Input 3 Invert
Short description
Set to 1 to invert digital input 3
Mode
Open‑loop
Minimum
0
Default
0
Type
8 Bit User Save
Display Format
Standard
Coding
RW, TE
Value
Text
0
Not.Inv
1
Invert
A value of 0 or 1 in Digital Input 3 Invert (08.013) allows the input state to be non-inverted(0) or inverted(1) respectively.
Digital Input 3 Invert (08.013) inverts the destination parameter Digital Input 03 Destination A (08.023) or DI 03 Destination B (08.123).
Parameter
08.014 Digital Input 4 Invert
Short description
Set to 1 to invert digital input 4
Mode
Open‑loop
Minimum
0
Default
0
Type
8 Bit User Save
Display Format
Standard
Coding
RW, TE
Value
Text
0
Not.Inv
1
Invert
A value of 0 or 1 in Digital Input 4 Invert (08.014) allows the input state to be non-inverted(0) or inverted(1) respectively.
Digital Input 4 Invert (08.014) inverts the destination parameter Digital Input 04 Destination A (08.024) or DI 04 Destination B (08.124).
Parameter
08.015 Digital Input 5 Invert
Short description
Set to 1 to invert digital input 5
Mode
Open‑loop
Minimum
0
Default
0
Type
8 Bit User Save
Display Format
Standard
Coding
RW, TE
Value
Text
0
Not.Inv
1
Invert
A value of 0 or 1 in Digital Input 5 Invert (08.015) allows the input state to be non-inverted(0) or inverted(1) respectively.
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
Maximum
1
Units
Update Rate
1ms
Decimal Places
0
Maximum
1
Units
Update Rate
Background read
Decimal Places
0
Maximum
1
Units
Update Rate
Background read
Decimal Places
0
Maximum
1
Units
Update Rate
Background read
Decimal Places
0
Maximum
1
Units
Update Rate
Background read
Decimal Places
0
Maximum
1
Units
Update Rate
Background read
Decimal Places
0
115

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents