Measured Values; A.10 Measured Values - Siemens siprotec 7SD5 User Manual

Line differential protection with distance protection
Hide thumbs Also See for siprotec 7SD5:
Table of Contents

Advertisement

A Appendix

A.10 Measured Values

No.
Description
-
Upper setting limit for IL1dmd (IL1dmd>)
-
Upper setting limit for IL2dmd (IL2dmd>)
-
Upper setting limit for IL3dmd (IL3dmd>)
-
Upper setting limit for I1dmd (I1dmd>)
-
Upper setting limit for Pdmd (|Pdmd|>)
-
Upper setting limit for Qdmd (|Qdmd|>)
-
Upper setting limit for Sdmd (Sdmd>)
-
Lower setting limit for Power Factor (PF<)
601
I L1 (IL1 =)
602
I L2 (IL2 =)
603
I L3 (IL3 =)
610
3I0 (zero sequence) (3I0 =)
611
3I0sen (sensitive zero sequence) (3I0sen=)
612
IY (star point of transformer) (IY =)
613
3I0par (parallel line neutral) (3I0par=)
619
I1 (positive sequence) (I1
620
I2 (negative sequence) (I2
621
U L1-E (UL1E=)
622
U L2-E (UL2E=)
623
U L3-E (UL3E=)
624
U L12 (UL12=)
625
U L23 (UL23=)
626
U L31 (UL31=)
627
Uen (Uen =)
631
3U0 (zero sequence) (3U0 =)
632
Usync (synchronism) (Usync =)
633
Ux (separate VT) (Ux
634
U1 (positive sequence) (U1
635
U2 (negative sequence) (U2
636
U-diff (line-bus) (Udiff =)
637
U-line (Uline =)
638
U-bus (Ubus =)
641
P (active power) (P =)
642
Q (reactive power) (Q =)
643
Power Factor (PF =)
644
Frequency (Freq=)
645
S (apparent power) (S =)
646
Frequency (busbar) (F-bus =)
647
Frequency (difference line-bus) (F-diff=)
648
Angle (difference line-bus) (ϕ-diff=)
649
Frequency (line) (F-line=)
679
U1co (positive sequence, compounding)
(U1co=)
684
U0 (zero sequence) (U0 =)
674
Function
Set Points(MV)
Set Points(MV)
Set Points(MV)
Set Points(MV)
Set Points(MV)
Set Points(MV)
Set Points(MV)
Set Points(MV)
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
=)
Measurement
=)
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
=)
Measurement
=)
Measurement
=)
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
IEC 60870-5-103
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
134
129
No
9
134
129
No
9
134
129
No
9
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
134
129
No
9
134
129
No
9
134
129
No
9
134
129
No
9
134
129
No
9
134
129
No
9
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
130
1
No
9
130
1
No
9
130
1
No
9
134
129
No
9
134
129
No
9
-
-
-
-
134
129
No
9
-
-
-
-
130
1
No
9
130
1
No
9
130
1
No
9
130
1
No
9
-
-
-
-
-
-
-
-
Configurable in Matrix
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
1
CFC
CD
DD
2
CFC
CD
DD
3
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
4
CFC
CD
DD
5
CFC
CD
DD
6
CFC
CD
DD
10
CFC
CD
DD
11
CFC
CD
DD
12
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
2
CFC
CD
DD
3
CFC
CD
DD
1
CFC
CD
DD
7
CFC
CD
DD
8
CFC
CD
DD
-
CFC
CD
DD
9
CFC
CD
DD
-
CFC
CD
DD
4
CFC
CD
DD
5
CFC
CD
DD
6
CFC
CD
DD
7
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
7SD5 Manual
C53000-G1176-C169-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents