2.5.1.6

Information List

No.
Information
3603
>BLOCK 21 Dist.
3610
>BLOCK Z1-Trip
3611
>ENABLE Z1B
3613
>ENABLE Z1Binst
3617
>BLOCK Z4-Trip
3618
>BLOCK Z5-Trip
3619
>BLOCK Z4 Ph-E
3620
>BLOCK Z5 Ph-E
3651
Dist. OFF
3652
Dist. BLOCK
3653
Dist. ACTIVE
3654
Dis.ErrorK0(Z1)
3655
DisErrorK0(>Z1)
3671
Dis. PICKUP
3672
Dis.Pickup L1
3673
Dis.Pickup L2
3674
Dis.Pickup L3
3675
Dis.Pickup E
3681
Dis.Pickup 1pL1
3682
Dis.Pickup L1E
3683
Dis.Pickup 1pL2
3684
Dis.Pickup L2E
3685
Dis.Pickup L12
3686
Dis.Pickup L12E
3687
Dis.Pickup 1pL3
3688
Dis.Pickup L3E
3689
Dis.Pickup L31
3690
Dis.Pickup L31E
3691
Dis.Pickup L23
3692
Dis.Pickup L23E
3693
Dis.Pickup L123
3694
Dis.Pickup123E
Dis Pickup ϕ L1
3695
Dis Pickup ϕ L2
3696
Dis Pickup ϕ L3
3697
3701
Dis.Loop L1-E f
3702
Dis.Loop L2-E f
3703
Dis.Loop L3-E f
3704
Dis.Loop L1-2 f
3705
Dis.Loop L2-3 f
3706
Dis.Loop L3-1 f
3707
Dis.Loop L1-E r
3708
Dis.Loop L2-E r
3709
Dis.Loop L3-E r
7SD5 Manual
C53000-G1176-C169-1
Type of In-
formation
SP
>BLOCK 21 Distance
SP
>BLOCK Z1-Trip
SP
>ENABLE Z1B (with setted Time Delay)
SP
>ENABLE Z1B instantanous (w/o T-Delay)
SP
>BLOCK Z4-Trip
SP
>BLOCK Z5-Trip
SP
>BLOCK Z4 for ph-e loops
SP
>BLOCK Z5 for ph-e loops
OUT
Distance is switched off
OUT
Distance is BLOCKED
OUT
Distance is ACTIVE
OUT
Setting error K0(Z1) or Angle K0(Z1)
OUT
Setting error K0(>Z1) or Angle K0(>Z1)
OUT
Distance PICKED UP
OUT
Distance PICKUP L1
OUT
Distance PICKUP L2
OUT
Distance PICKUP L3
OUT
Distance PICKUP Earth
OUT
Distance Pickup Phase L1 (only)
OUT
Distance Pickup L1E
OUT
Distance Pickup Phase L2 (only)
OUT
Distance Pickup L2E
OUT
Distance Pickup L12
OUT
Distance Pickup L12E
OUT
Distance Pickup Phase L3 (only)
OUT
Distance Pickup L3E
OUT
Distance Pickup L31
OUT
Distance Pickup L31E
OUT
Distance Pickup L23
OUT
Distance Pickup L23E
OUT
Distance Pickup L123
OUT
Distance Pickup123E
OUT
Dist.: Phi phase L1 Pickup
OUT
Dist.: Phi phase L2 Pickup
OUT
Dist.: Phi phase L3 Pickup
OUT
Distance Loop L1E selected forward
OUT
Distance Loop L2E selected forward
OUT
Distance Loop L3E selected forward
OUT
Distance Loop L12 selected forward
OUT
Distance Loop L23 selected forward
OUT
Distance Loop L31 selected forward
OUT
Distance Loop L1E selected reverse
OUT
Distance Loop L2E selected reverse
OUT
Distance Loop L3E selected reverse
2.5 Distance Protection