Addr.
Parameter
2650
3I0p PICKUP
2652
T 3I0p TimeDial
2653
TimeDial TD3I0p
2656
T 3I0p Add
2660
IEC Curve
2661
ANSI Curve
2670
I(3I0)p Tele/BI
2671
I(3I0)p SOTF
2680
SOTF Time DELAY
2801
DMD Interval
2802
DMD Sync.Time
2811
MinMax cycRESET
2812
MiMa RESET TIME
2813
MiMa RESETCYCLE
2814
MinMaxRES.START
2901
MEASURE. SUPERV
2902A
BALANCE U-LIMIT
2903A
BAL. FACTOR U
2904A
BALANCE I LIMIT
2905A
BAL. FACTOR I
ΣI THRESHOLD
2906A
ΣI FACTOR
2907A
2908A
T BAL. U LIMIT
2909A
T BAL. I LIMIT
2910
FUSE FAIL MON.
2911A
FFM U>(min)
2912A
FFM I< (max)
2913A
FFM U<max (3ph)
2914A
FFM Idelta (3p)
2915
V-Supervision
7SD5 Manual
C53000-G1176-C169-1
Function
C
Setting Options
0.05 .. 4.00 A; ∞
Back-Up O/C
1A
0.25 .. 20.00 A; ∞
5A
0.05 .. 3.00 sec; ∞
Back-Up O/C
0.50 .. 15.00 ; ∞
Back-Up O/C
Back-Up O/C
0.00 .. 30.00 sec
Back-Up O/C
Normal Inverse
Very Inverse
Extremely Inv.
LongTimeInverse
Back-Up O/C
Inverse
Short Inverse
Long Inverse
Moderately Inv.
Very Inverse
Extremely Inv.
Definite Inv.
Back-Up O/C
NO
YES
Back-Up O/C
NO
YES
Back-Up O/C
0.00 .. 30.00 sec
Demand meter
15 Min., 1 Sub
15 Min., 3 Subs
15 Min.,15 Subs
30 Min., 1 Sub
60 Min., 1 Sub
Demand meter
On The Hour
15 After Hour
30 After Hour
45 After Hour
Min/Max meter
NO
YES
Min/Max meter
0 .. 1439 min
Min/Max meter
1 .. 365 Days
Min/Max meter
1 .. 365 Days
Measurem.Superv
ON
OFF
Measurem.Superv
10 .. 100 V
Measurem.Superv
0.58 .. 0.95
Measurem.Superv
1A
0.10 .. 1.00 A
5A
0.50 .. 5.00 A
Measurem.Superv
0.10 .. 0.95
Measurem.Superv
1A
0.10 .. 2.00 A
5A
0.50 .. 10.00 A
Measurem.Superv
0.00 .. 0.95
Measurem.Superv
5 .. 100 sec
Measurem.Superv
5 .. 100 sec
Measurem.Superv
ON
OFF
Measurem.Superv
10 .. 100 V
Measurem.Superv
1A
0.10 .. 1.00 A
5A
0.50 .. 5.00 A
Measurem.Superv
2 .. 100 V
Measurem.Superv
1A
0.05 .. 1.00 A
5A
0.25 .. 5.00 A
Measurem.Superv
w/ CURR.SUP
w/ I> & CBaux
OFF
Default Setting
∞ A
3I0p Pickup
∞ A
0.50 sec
T 3I0p Time Dial
5.00
Time Dial TD 3I0p
0.00 sec
T 3I0p Additional Time Delay
Normal Inverse
IEC Curve
Inverse
ANSI Curve
NO
Instantaneous trip via Tele-
prot./BI
NO
Instantaneous trip after Switch-
OnToFault
0.00 sec
Trip time delay after SOTF
60 Min., 1 Sub
Demand Calculation Intervals
On The Hour
Demand Synchronization Time
YES
Automatic Cyclic Reset Function
0 min
MinMax Reset Timer
7 Days
MinMax Reset Cycle Period
1 Days
MinMax Start Reset Cycle in
ON
Measurement Supervision
50 V
Voltage Threshold for Balance
Monitoring
0.75
Balance Factor for Voltage
Monitor
0.50 A
Current Balance Monitor
2.50 A
0.50
Balance Factor for Current
Monitor
0.25 A
Summated Current Monitoring
Threshold
1.25 A
0.50
Summated Current Monitoring
Factor
5 sec
T Balance Factor for Voltage
Monitor
5 sec
T Current Balance Monitor
ON
Fuse Failure Monitor
30 V
Minimum Voltage Threshold U>
0.10 A
Maximum Current Threshold I<
0.50 A
5 V
Maximum Voltage Threshold U<
(3phase)
0.10 A
Delta Current Threshold
(3phase)
0.50 A
w/ CURR.SUP
Voltage Failure Supervision
A.7 Settings
Comments
627