Omron NJ501-1400 User Manual page 68

Nj-series cpu unit hardware
Hide thumbs Also See for NJ501-1400:
Table of Contents

Advertisement

2 System Configuration
 Units
NJ-series CPU Units
I/O capacity/Maximum
number of Configura-
Model
tion Units (Maximum
number of Expansion
NJ501-1500
2,560 points/40 Units (3
Expansion Racks)
NJ501-1400
NJ501-1300
NJ501-4500
NJ501-4400
NJ501-4300
NJ501-4310
NJ501-1520
NJ501-1420
NJ501-1320
NJ501-4320
NJ501-1340
NJ301-1200
NJ301-1100
NJ101-1000
NJ101-9000
NJ101-1020
NJ101-9020
NJ-series Power Supply Units
Model
NJ-PA3001
NJ-PD3001
Note A CJ-series Power Supply Unit cannot be used to supply power to an NJ-system CPU Rack or Expansion
Rack.
If you connect a CJ-series Power Supply Unit to a CPU Rack, an Incorrect Power Supply Unit Connected
error will occur, and the CPU Unit will not operate. The RUN indicator will flash at a 3-s interval and the
ERROR indicator will light.
If you connect the Power Supply Unit to an Expansion Rack, operation is performed without error detection.
Normal operation, however, may be unstable due to insufficient supplied power. Also, an Internal NJ-series
Bus Check Error (i.e., a Controller error in the major fault level) may occur when the power is interrupted.
Note The Power Supply Unit may continue to supply power to the rest of the Controller for a few seconds after the
power supply turns OFF and the PWR indicator is lit during this time. If the NJ-series NJ-PD3001 Power
Supply Unit is used, confirm that the PWR indicator is not lit when the power supply is tuned ON again after
the power supply turns OFF.
Precautions for Safe Use
• Do not use the Power Supply Units in the system beyond the rated supply capacity ranges.
Doing so may result in operation stopping, incorrect operation, or failure to correctly back up
required data at power interruptions.
2-6
Pro-
gram
capac-
ity
Racks)
20 MB
5 MB
3 MB
Output current
Power supply
voltage
5 VDC
100 to 240 VAC
6.0 A
24 VDC
6.0 A
Data-
Num-
Memory
base
ber of
capacity for
connec-
motion
variables
tion ser-
axes
vice
2 MB:
64
Not sup-
Retained
ported.
32
during
16
power inter-
ruptions.
64
4 MB: Not
32
retained
16
during
power inter-
ruptions.
64
Sup-
ported.
32
16
Not sup-
ported.
0.5 MB:
8
Retained
4
during
2
power inter-
ruptions.
0
2 MB: Not
2
Sup-
retained
ported.
0
during
power inter-
ruptions.
Output
RUN
capacity
output
24 VDC
1.0 A
30 W
Yes
1.0 A
30 W
Yes
NJ-series CPU Unit Hardware User's Manual (W500)
Current
consump-
GEM
Robot
tion
Ser-
con-
vices
trol
5
24
VDC
VDC
Not
Not
1.90
---
sup-
sup-
A
ported.
ported.
Sup-
ported.
Not
sup-
ported.
Sup-
ported.
Sup-
Not
ported.
sup-
ported.
Not
sup-
ported.
CPU
Expansion
Weight
Rack
Racks
Yes
Yes
470 g
max.
Yes
Yes
490 g
max.
Wei
ght
550
g

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents