CAPONORD 1200
shorted to positive / open circuit, shorted to negative.
Error cause
If shorted to positive: excessive voltage has been detected at PIN 58; if the circuit is open,
shorted to negative: voltage equal to zero has been detected.
DIAGNOSTICS INSTRUMENT: LOGIC ERRORS
Starter switch P0169
signal not valid.
Error cause
Fault in the switch (lock) of the engine start-up. The instrument panel does not indicate the
presence of this error even in the ATT status.
Troubleshooting
Check the locking cause and restore.
Lights list
Headlamp
Characteristic
Front daylight running lights
2V - 5W W5WB x 2
Low beam light
12V - 55W H11 x 2
High beam light
12V - 55W H11
Taillight
Characteristic
Rear daylight running light / stop light
LED
Electrical system
ELE SYS - 95