Download Print this page

APRILIA CAPONORD 1200 Service Station Manual page 137

Advertisement

CAPONORD 1200
relay and injector activation. The continuity of the wiring is necessary for correct activation:
no error indications are displayed in case of lack of activation.
Internal rear cylinder injector
The auxiliary injection relay (No. 46 in the wiring diagram, placed in the front relay box, left
side; CHECK, however, the identification of the relay with the colour of the cables) is ener-
gised for 5 seconds and the injector cable connected to control unit is closed to ground for
4 ms per second. Disconnect the 4-way connector of the fuel pump to be able to hear the
relay and injector activation. The continuity of the wiring is necessary for correct activation:
no error indications are displayed in case of lack of activation.
External front cylinder injector
The auxiliary injection relay (No. 46 in the wiring diagram, placed in the front relay box, left
side; CHECK, however, the identification of the relay with the colour of the cables) is ener-
gised for 5 seconds and the injector cable connected to control unit is closed to ground for
4 ms per second. Disconnect the 4-way connector of the fuel pump to be able to hear the
relay and injector activation. The continuity of the wiring is necessary for correct activation:
no error indications are displayed in case of lack of activation.
External rear cylinder injector
The auxiliary injection relay (No. 46 in the wiring diagram, placed in the front relay box, left
side; CHECK, however, the identification of the relay with the colour of the cables) is ener-
gised for 5 seconds and the injector cable connected to control unit is closed to ground for
4 ms per second. Disconnect the 4-way connector of the fuel pump to be able to hear the
relay and injector activation. The continuity of the wiring is necessary for correct activation:
no error indications are displayed in case of lack of activation.
DIAGNOSTICS INSTRUMENT: ELECTRICAL ERRORS
External front cylinder injector P0201
short circuit to positive/ short circuit to negative / open circuit
Error cause
If shorted to positive: excessive voltage has been detected at PIN 8. If shorted to negative:
no voltage has been detected. If the circuit is open: an interruption has been detected.
Troubleshooting
If shorted to positive: disconnect the injector connector, set key to ON, activate the compo-
nent with the diagnosis instrument and check the voltage on the white/green cable on the
injector connector. If following the activation the voltage does not drop, restore the cabling,
otherwise replace the injector.
Electrical system
ELE SYS - 137

Advertisement

loading