CAPONORD 1200
•
Travel limits not acquired / Manual / Automatic / Fault
Exhaust butterfly valve automatic
•
Indeterminate / Seek / Verify / Adjustment / Fault / Zero
Front Suspension Valve
•
Operation / Constant Current Fault / Zero Current Fault
Rear suspension valve
•
Operation / Constant Current Fault / Zero Current Fault
Cruise Control button
•
Released / Pressed / Short-circuit Fault / Open Circuit Fault / Indeterminate Fault
Switch front brake
•
Released / Pressed / Short-circuit Fault / Open Circuit Fault
Switch rear brake
•
Released / Pressed / Short-circuit Fault / Open Circuit Fault
Exhaust butterfly valve output
•
Not active / Active / Short-circuit Fault / Open Circuit Fault
Preload motor control output
•
Not active / Active / Short-circuit Fault / Open Circuit Fault
Rotary sensor reset
•
Not Carried out / Carried out
DIAGNOSTICS INSTRUMENT: ACTIVATION
•
Reset control unit
•
Front Suspension Valve
•
Rear suspension valve
•
Exhaust butterfly valve
•
Preload motor
DIAGNOSTICS INSTRUMENT: ERRORS
Error VCU code C1000
Error cause
•
The stored IDMODELV and the current one do not coincide: the VCU is programmed for a
vehicle different from the one on which it is fitted.
Troubleshooting
•
Replace the motor control unit or perform the reset of the VCU using a diagnosis instrument.
Control unit internal error C1200
Error cause
Electrical system
ELE SYS - 109