CAPONORD 1200
Pin out:
1 blue/green cable: ground connection
2 yellow/red cable: 5 V
CAUTION
BEFORE CARRYING OUT ANY TROUBLESHOOTING,
CAREFULLY READ THE GENERAL TROUBLESHOOTING
CONCEPTS FOR ELECTRICAL DEVICES AT THE BEGIN-
NING OF THE CHECK AND CONTROL SECTION IN THE
ELECTRICAL SYSTEM CHAPTER.
DIAGNOSTICS INSTRUMENT: STATUSES
RUN / STOP switch
Run/Stop
NOTES
Indication on the diagnostics instrument always on STOP: disconnect the connector and,
with the switch set to RUN, check if there is continuity towards the two cables switch - Blue/
Green and Yellow/Red: If there is not continuity, replace the sensor; if there is continuity,
check the connector: if not OK, restore the cable harness; if OK, check, with key set to ON,
if there is voltage on Yellow/Red cable: if there is no voltage, restore the cable harness; if
there is, check the Yellow/Red cable ground insulation: If there is continuity with ground
connection, restore the cable harness; if OK, set the key to OFF and check the VEHICLE
connector and the engine-vehicle cable harness connector: if it is not OK, restore; if it is OK,
check the continuity of the Yellow/Red cable between the switch connector and VEHICLE
connector PIN 78: if not OK, restore the cable harness; if OK, replace the Marelli control
unit.
Indication on the diagnostics instrument always on RUN: disconnect the connector and, with
the switch set to STOP, check if there is continuity between the two cables of the switch: if
there is continuity, replace the switch; otherwise, it means that, with key set to ON, the
Yellow/Red cable (between switch and the PIN 78 of the control unit connector) is shorted
to positive: restore the cable harness.
Butterfly valve in exhaust
Function
It optimised the operation of the engine at low rev-
olutions without compromising the efficiency of the
exhaust system at high revolutions.
Operation / Operating principle
The system consists of a throttle valve with a re-
turn spring placed on the exhaust pipe. Two cables
operated by an electric motor control the closing
Electrical system