Download Print this page

APRILIA CAPONORD 1200 Service Station Manual page 173

Advertisement

CAPONORD 1200
road surface and it adapts the calibration of the
suspension in real time in order to maximise com-
fort and keep the correct setup of the motorbike.
Level in electrical circuit diagram:
VCU (Vehicle Control Unit) control unit
Location:
On the vehicle: in the upper part from
the active fork leg (LH) of the fork.
Connector: on the component.
Pin out:
1. Ground from VCU
2. Temperature signal output
3. Supply from VCU
4. Pressure signal output
DIAGNOSTICS INSTRUMENT: ELECTRICAL ERRORS
VCU ERRORS
Error pressure sensor shortcircuit C1407
Error cause
An excessive tension or a null tension has been detected on PIN A3 VCU.
Troubleshooting
Disconnect the connector of the sensor and check its insulation from ground and supply
system of PIN 4: if the insulation is not present, restore the cabling, otherwise replace the
sensor.
Error pressure sensor open circuit C1408
Error cause
An interruption of the circuit has been detected.
Troubleshooting
Check the connector on the component and the VCU connector. Disconnect the two con-
nectors and check the continuity of the cable between PIN 4 sensor and PIN A3 VCU and
restore the cable harness. If the cable harness is not damaged, replace the sensor.
Error temperature sensor shortcircuit C1409
Error cause
An excessive or null tension has been detected on PIN D1 VCU.
Troubleshooting
Electrical system
ELE SYS - 173

Advertisement

loading