CAPONORD 1200
•
Unscrew and remove the two nuts fix-
ing the protection.
•
Collect the protection.
•
Remove the oil pump.
Inspection
•
Undo and remove the two fixing
screws.
•
Using a thickness gauge check clear-
ance between rotor and stator and re-
place the rotor / stator unit if necessary.
clearance between rotor and stator: 0.04 ± 0.10
mm (0.0016 in - 0.0039 in).
Engine
ENG - 289