Issue 6.0
Alarm Report Example:
The report example below shows an alarm for all busy Station and Trunk DSPs.
<< ALARM REPORT >>
LVL NO STAT
-------------------------------------------------------------------------------
MAJ 0068 ERR 01/22/09 09:30 VoIP All DSP Busy
MAJ 0068 ERR 01/22/09 09:31 VoIP All DSP Busy
MIN 0002 REC 01/22/09 09:32 PKG Installation
LCD Display
Clock/Calendar
VoIP All Busy XX
Soft Key
S
S
2
ERVICE
ECTION
12 - 2
DATE
TIME
LCD Display Indication
C
ONDITIONS
When using IP Phones, the alarm is shown on both terminals involved in that
call if they are both on the same system.
The alarm cannot be displayed on Standard SIP Phones or Single Line phones.
If a call from a Standard SIP telephone to a Multiline telephone cannot be
established due to an All DSP Busy condition, the Multiline telephone will not
display the "All DSP" busy message.
If a SIP trunk call is sent to the SL1100 when all DSP resources are busy, the
call is rejected but the alarm is not displayed on any system telephone.
The default alarm setting is Minor.
01/22/2009 23:37
ITEM
UNIT
VoIPDB
VoIPDB
PRIU
XX = Slot number of CPU with VoIPDB.
NEC SL1100
SLT PRT PARAMETER
01 00 STA
01 00 TRK
02 00
Note
All DSP Busy Indication