Sip Protocol - NEC SL1100 Networking Manual

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

NEC SL1100
Program/Item
No.
10-23-02
SIP System Interconnection
Setup – IP Address
10-23-04
SIP System Interconnection
Setup – Dial Number
6.8
Program/Item
No.
SIP Trunk Basic Information
84-14-06
Setup – SIP Trunk Port
Number
84-14-07
SIP Trunk Basic Information
Setup – Session Timer
Value
84-14-08
SIP Trunk Basic Information
Setup – Minimum Session
Timer Value
Networking Manual
Description/
Selection
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
Default is 0.0.0.0
Up to 12 digits (0 ~ 9)
Default not assigned

SIP Protocol

Description/
Selection
1 ~ 65535
Default is 5060 = Profile 1
0 ~ 65535 seconds
Default is 0
0 ~ 65535 seconds
Default is 1800
Assigned Data
Assigned Data
5062 = Profile 2
Version 5.0 or higher: Select SIP
Profile 1-2.
Version 5.0 or higher: Select SIP
Profile 1-2.
Version 5.0 or higher: Select SIP
Profile 1-2.
Issue 6.0
Comments
Define the IP address of
another system.
Determine another system call
control port number.
Comments
Set the SIP UA (User
Authorized) Trunk port number
(Receiving Transport for NEC
SL1100 SIP).
Set the Session Timer Value.
0 means session timer is Off
Set the Minimum Session Timer
Value.
7 - 25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents