Siemens SINAMICS G120D Operating Instructions Manual page 337

With control units cu250d-2
Hide thumbs Also See for SINAMICS G120D:
Table of Contents

Advertisement

Number
Cause
A07457
Combination of input signals is not
permissible
F07458
Reference cam not found
F07459
No zero mark available
F07460
End of reference cam not found
A07461
Reference point not set
A07462
Selected traversing block number
does not exist
A07463
External block change not request-
ed in the traversing block
F07464
Traversing block is inconsistent
A07465
Traversing block does not have a
subsequent block
A07466
Traversing block number assigned
a multiple number of times
A07467
Traversing block has illegal task
parameters
A07468
Traversing block jump target does
not exist
Converter with control units CU250D-2
Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB
Remedy
An illegal combination of input signals, which are simultaneously set was
detected, e.g.:
Jog 1 and jog 2 (p2589, p2590).
Jog 1 or jog 2 and direct setpoint input/MDI (p2589, p2590, p2647).
Jog 1 or jog 2 and start referencing (p2589, p2590, p2595).
Jog 1 or jog 2 and activate traversing task (p2589, p2590, p2631).
Direct setpoint input/MDI and start referencing (p2647, p2595).
Direct setpoint input/MDI and activate traversing task (p2647, p2631).
Start referencing and activate traversing task (p2595, p2631).
After starting the reference point approach, the axis has traversed
through the maximum permissible distance to search for the reference
cam without finding the reference cam. Remedy:
Check the "reference cam" binector input (BI: p2612).
Check the maximum permissible distance to the reference cam
(p2606).
If axis does not have a reference cam, then set p2607 to 0.
After leaving the reference cam, the axis traversed through the maximum
permissible distance between the reference cam and zero mark without
finding the zero mark. Remedy:
Check the encoder regarding the zero mark.
Check the maximum permissible distance between the reference cam
and zero mark (p2609).
Use an external encoder zero mark (p0494).
During the reference point approach, the axis, when approaching the zero
mark, has reached the end of the traversing range without identifying an
edge at the binector input "Reference cam" (BI: p2612). Remedy:
Check the "reference cam" binector input (BI: p2612).
Reference the system
Correct the traversing program.
Resolve the reason why the edge is missing at binector input (BI: p2632).
Check the traversing block and, if necessary, take into consideration any
alarms that are present.
Parameterize this traversing block with the step enabling condition
END.
Parameterize additional traversing blocks with a higher block number
and for the last block, parameterize the step enabling condition END.
Correct the traversing blocks.
Correct the task parameter in the traversing block.
Correct the traversing block.
Add the missing traversing block.
Alarms, faults and system messages
10.6 List of alarms and faults
337