Alarms, faults and system messages
10.2 Faults
Parameters of the fault buffer and the fault history
Parameter
r0945
r0948
r0949
p0952
r2109
r2130
r2131
r2133
r2136
326
Description
Fault code
Displays the numbers of faults that have occurred
Fault time received in milliseconds
Displays the time in milliseconds when the fault occurred
Fault value
Displays additional information about the fault
Fault cases, counter
Number of fault cases that have occurred since the last acknowledgment.
The fault buffer is deleted with p0952 = 0.
Fault time removed in milliseconds
Displays the time in milliseconds when the fault occurred
Fault time received in days
Displays the time in days when the fault occurred
Actual fault code
Displays the code of the oldest fault that is still active
Fault value for float values
Displays additional information about the fault that occurred for float values
Fault time removed in days
Displays the time in days when the fault was removed
Converter with control units CU250D-2
Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB