Lenovo HX1310 Installation And Service Manual page 66

Converged systems converged hx series
Table of Contents

Advertisement

The integrated management module 2.1 (IMM2.1) combines service processor functions, video controller,
and remote presence and blue-screen capture features in a single chip. The IMM provides advanced
service-processor control, monitoring, and alerting function. If an environmental condition exceeds
a threshold or if a system component fails, the IMM lights LEDs to help you diagnose the problem,
records the error in the IMM event log, and alerts you to the problem. Optionally, the IMM also provides a
virtual presence capability for remote server management capabilities. The IMM provides remote server
management through the following industry-standard interfaces:
– Intelligent Platform Management Protocol (IPMI) version 2.0
– Simple Network Management Protocol (SNMP) version 3
– Common Information Model (CIM)
– Web browser
For more information about the integrated management module 2.1 (IMM2.1), see "Using the
integrated management module" on page 36, Appendix A "Integrated management module 2.1
(IMM2.1) error messages" on page 179, and the Integrated Management Module II User's Guide at
http://publib.boulder.ibm.com/infocenter/systemx/documentation/topic/com.lenovo.sysx.imm2.doc/
product_page.html.
• Dynamic System Analysis
DSA Preboot
DSA Preboot diagnostic program is stored in the integrated USB memory on the server. DSA Preboot
collects and analyzes system information to aid in diagnosing server problems, as well as offering a
rich set of diagnostic tests of the major components of the server. DSA Preboot collects the following
information about the server:
– Drive health information
– Event logs for service processors
– IMM2.1 configuration information
– IMM2.1 environmental information
– Installed hardware, including PCI and USB information
– Light path diagnostics status
– Microprocessor, input/output hub, and UEFI error logs
– Network interfaces and settings
– Option card driver and firmware information
– RAID controller configuration
– Service processor (integrated management module) status and configuration
– System configuration
– Vital product data, firmware, and UEFI configuration
DSA Preboot also provides diagnostics for the following system components (when they are installed):
1. Emulex network adapter
2. IMM I2C bus
3. Memory modules
4. Microprocessors
5. SAS or SATA drives
6. LSI controller
7. Broadcom network adapter
8. FusionIO storage
52