Lenovo HX1310 Installation And Service Manual page 392

Converged systems converged hx series
Table of Contents

Advertisement

• 806f000f-2201ffff : The System [ComputerSystemElementName] encountered a POST Error. (ABR
Status)
This message is for the use case when an implementation has detected a Post Error.
May also be shown as 806f000f2201ffff or 0x806f000f2201ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0184
User Response
This is a UEFI detected event. The UEFI(POST) error code for this event can be found in the logged
IMM message text. Please refer to the UEFI(POST) error code in the "UEFI(POST) error code" section
of the Information Center for the appropriate user response. Firmware Error : Sys Boot Status : X8
PCI 2 Firm : X8 PCI 3 Firm :
• 806f0013-1701ffff : A diagnostic interrupt has occurred on system [ComputerSystemElementName].
(NMI State)
This message is for the use case when an implementation has detected a Front Panel NMI / Diagnostic
Interrupt.
May also be shown as 806f00131701ffff or 0x806f00131701ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0222
User Response
378
HX1310, HX2310-E, HX3310, HX3310-F Installation and Service Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx3310Hx2310-eHx3310-f

Table of Contents