Lenovo HX1310 Installation And Service Manual page 677

Converged systems converged hx series
Table of Contents

Advertisement

May also be shown as 816f000d0410ffff or 0x816f000d0410ffff
Severity
Info
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
816f000f-2201ffff : The System [ComputerSystemElementName] has detected a POST Error
deassertion. (ABR Status)
This message is for the use case when an implementation has detected that Post Error has deasserted.
May also be shown as 816f000f2201ffff or 0x816f000f2201ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0185
User Response
No action; information only. Firmware Error : Sys Boot Status : X8 PCI 2 Firm : X8 PCI 3 Firm :
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
663

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx3310Hx2310-eHx3310-f

Table of Contents