Lenovo HX1310 Installation And Service Manual page 497

Converged systems converged hx series
Table of Contents

Advertisement

Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0232
User Response
1. Check the PCI LED.
2. Reseat the affected adapters and riser cards.
3. Update the server firmware (UEFI and IMM) and adapter firmware. Important: Some cluster
solutions require specific code levels or coordinated code updates. If the device is part of a
cluster solution, verify that the latest level of code is supported for the cluster solution before
you update the code.
4. Remove both adapters.
5. Replace the PCIe adapters.
6. Replace the riser card.
• 806f0507-0301ffff : [ProcessorElementName] has a Configuration Mismatch. (CPU 1)
This message is for the use case when an implementation has detected a Processor Configuration
Mismatch has occurred.
May also be shown as 806f05070301ffff or 0x806f05070301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0062
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
483

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx3310Hx2310-eHx3310-f

Table of Contents