Lenovo HX1310 Installation And Service Manual page 672

Converged systems converged hx series
Table of Contents

Advertisement

816f000d-0406ffff : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 6)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0406ffff or 0x816f000d0406ffff
Severity
Info
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
816f000d-0407ffff : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 7)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0407ffff or 0x816f000d0407ffff
Severity
Info
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
658
HX1310, HX2310-E, HX3310, HX3310-F Installation and Service Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx3310Hx2310-eHx3310-f