1. Make sure that the installed microprocessors are compatible with each other (see Installing a
microprocessor and heat sink for information about microprocessor requirements).
2. Update the server firmware to the latest level (see Updating the firmware).
3. (Trained technician only) Replace the incompatible microprocessor.
One of the CPUs :
• 806f0608-1301ffff : [PowerSupplyElementName] has a Configuration Mismatch. (PS Configuration)
This message is for the use case when an implementation has detected a Power Supply with a
Configuration Error.
May also be shown as 806f06081301ffff or 0x806f06081301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0104
User Response
1. Make sure that the power supplies installed are with the same rating or wattage.
2. Reinstall the power supplies with the same rating or wattage.
• 806f060d-0400ffff : Array [ComputerSystemElementName] has failed. (Drive 0)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0400ffff or 0x806f060d0400ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
518
HX1310, HX2310-E, HX3310, HX3310-F Installation and Service Guide