Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0392
User Response
If there is no GPU/storage tray installed in the system, then the log event is a normal condition. If
there is a GPU/storage tray installed in the system, then check the following two portions:
1. PDB (Power Distribution Board) cable is correctly connected from riser card to PDB.
2. Replace another PDB cable.
• 806f0125-1002ffff : [ManagedElementName] detected as absent. (PCI Riser 2)
This message is for the use case when an implementation has detected a Managed Element is Absent.
May also be shown as 806f01251002ffff or 0x806f01251002ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0392
User Response
If there is no GPU/storage tray installed in the system, then the log event is a normal condition. If
there is a GPU/storage tray installed in the system, then check the following two portions:
1. PDB (Power Distribution Board) cable is correctly connected from riser card to PDB.
2. Replace another PDB cable.
• 806f0125-2c01ffff : [ManagedElementName] detected as absent. (ML2 Card)
This message is for the use case when an implementation has detected a Managed Element is Absent.
May also be shown as 806f01252c01ffff or 0x806f01252c01ffff
Severity
Info
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
423