Lenovo HX1310 Installation And Service Manual page 317

Converged systems converged hx series
Table of Contents

Advertisement

1. Reduce the ambient temperature.
2. Ensure the air baffle is installed correctly.
3. Check the server airflow. Make sure that nothing is blocking the air from coming into or
preventing the air from exiting the server.
• 80010701-1404ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (DIMM CD VR Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107011404ffff or 0x800107011404ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Reduce the ambient temperature.
2. Ensure the air baffle is installed correctly.
3. Check the server airflow. Make sure that nothing is blocking the air from coming into or
preventing the air from exiting the server.
• 80010701-1405ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (DIMM EF VR Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107011405ffff or 0x800107011405ffff
Severity
Warning
Serviceable
Yes
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
303

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx3310Hx2310-eHx3310-f

Table of Contents