Lenovo HX1310 Installation And Service Manual page 401

Converged systems converged hx series
Table of Contents

Advertisement

Yes
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0086
User Response
1. Reseat power supply n.
2. If the power-on LED is not lit and the power-supply error LED is lit, replace power supply n.
3. If both the power-on LED and the power-supply error LED are not lit, see Power problems for
more information. (n = power supply number)
• 806f0109-1301ffff : [PowerSupplyElementName] has been Power Cycled. (Host Power)
This message is for the use case when an implementation has detected a Power Unit that has been
power cycled.
May also be shown as 806f01091301ffff or 0x806f01091301ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0108
User Response
No action; information only.
806f010c-2001ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM 1)
This message is for the use case when an implementation has detected a Memory uncorrectable error.
May also be shown as 806f010c2001ffff or 0x806f010c2001ffff
Severity
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
387

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx3310Hx2310-eHx3310-f

Table of Contents