17.4.2
Communication detail settings
Make the settings according to the usage environment.
■1. Video Setting
Item
*1
Video Input Signal
*2
Video Resolution
*1
*2
■2. IP Address Setting for Multimedia Unit
Set the network settings for connecting from the multimedia unit via Ethernet.
Item
IP Address
Subnet Mask
Default Gateway
17 - 8
17.4 GOT Side Settings
Set the video input signal.
(Default: NTSC)
Set the video resolution.
When NTSC format is selected, the resolution is fixed to 640 480.When PAL format is selected, the resolution is fixed to
768 576.
For GT2710-V and GT2708-V, the resolution is fixed to 640 480.
Set the IP address of the multimedia unit.
(Default: 192.168.3.51)
Set the subnet mask for the sub network. (Only for connection via
router) If the sub network is not used, the default value is set. (Default:
255.255.255.0)
Set the router address of the default gateway on the side to which the
multimedia unit is connected. (Only for connection via router)
(Default: 0.0.0.0)
POINT
POINT
POINT
Network settings with the utility
The network setting can be changed on the Utility's [Communication setting] after writing
[Controller Setting] of project data.
For details on the Utility, refer to the following manual.
GOT2000 Series User's Manual (Utility)
Description
Description
Range
NTSC, PAL
640 480,
720 480,
768 576
Range
0.0.0.0 to 255.255.255.255
0.0.0.0 to 255.255.255.255
0.0.0.0 to 255.255.255.255