Remote Register Details; Initial Data Setting - Mitsubishi Electric RFID ECL2-V680D1 User Manual

Interface module
Table of Contents

Advertisement

3. SPECIFICATIONS

3.6 Remote Register Details

3.6.1 Initial data setting

Specification
Name
*3
Value
0000
Trigger
H
0001
Auto
H
0002
Repeat auto
H
0003
FIFO trigger
H
0004
FIFO repeat
H
3 - 13
(1) Communication specification area (RWwm+0H)
The communication specification method is selected according to the ID tag status
(stationary or moving). For details of the control method for each communication
specification, refer to Section 6.3, "Control Method by Communication Specification".
The contents set become enabled when the initial data setting request flag (RY(n+k)9)
turns ON.
Table 3.12 Communication Specification Area
(1)
Communicates with a static ID tag located within the antenna communication area when
*1
the ID command execution request (RYn4) turns ON.
(2)
Be sure that there is only one ID tag in the antenna communication area.
(1)
Waits for detection of an ID tag moving within the antenna communication area after the ID
command execution request (RYn4) turns ON, and then executes communication.
(2)
Be sure that there is only one ID tag in the antenna communication area.
(1)
Waits for detection of an ID tag moving within the antenna communication area after the ID
command execution request (RYn4) turns ON, and then executes communication.
(2)
Does not execute communication with ID tags that stay in the communication area.
(3)
Waits again for the approach of a moving ID tag after response transmission is completed,
continually executes communication with subsequent ID tags, and stops communication
when the ID command execution request (RYn4) turns OFF.
(4)
Be sure that there is only one ID tag in the antenna communication area.
(1)
Communicates with an operable ID tag within the antenna communication area after the ID
command execution request (RYn4) turns ON.
(2)
Sets the ID tag to an operation disabled state after communication completion.
*2
(3)
Does not communicate with an ID tag with which communication was once already
performed when that same ID tag is within the communication area.
(4)
Be sure that only one operable ID tag is within the antenna communication area during ID
tag communication.
(1)
Waits for detection of an operable ID tag within the antenna communication area after the
ID command execution request (RYn4) turns ON, and then performs communication.
(2)
Sets the ID tag to an operation disabled state after communication completion.
(3)
Does not communicate with the same ID tag again when an ID tag with which
communication was once already performed is within the communication area.
*2
(4)
Be sure that only one operable ID tag is within the antenna communication area during ID
tag communication.
(5)
Waits again for the approach of a moving ID tag after response transmission completion,
continuously executes communication with subsequent ID tags, and stops communication
when the ID command execution request (RYn4) turns OFF.
*1. The value is set to trigger by default.
*2. Cannot be used for communication with V680-D1KP□□.
*3. If an out-of-range value is specified, error detection (RXn5) turns ON. The set
contents are not updated.
Description
3 - 13

Advertisement

Table of Contents
loading