System Configuration; Connection Diagram - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

7.2

System Configuration

7.2.1
Connecting to PROFIBUS DP master equipment
PROFIBUS DP
master equipment
Communication
Controller
Type
PROFIBUS DP
master
PROFIBUS DP
equipment
*1
The maximum distance varies depending on the transmission speed. Confirm the specification on the PROFIBUS DP master
equipment side.
*2
Install the communication module (ABCC-M40-DPV1, Type number: AB6910-B or AB6910-C) manufactured by HMS to the
GT25-FNADP
The communication module manufactured by HMS must be prepared by the user.
For the communication module installation method, refer to the following manual.
*3
The number of connectable GOT modules (PROFIBUS DP slave equipment) to one PROFIBUS DP master equipment varies
depending on the presence/absence of repeater units. Up to 9 repeater units can be used.
When repeater units are not installed: Up to 32 GOT modules (PROFIBUS DP slave equipment) can be connected to each
segment.
When repeater units are installed: Up to 125 GOT modules (PROFIBUS DP slave equipment) can be connected to each
segment.
Connection cable
Connection cable
Connection diagram number
PROFIBUS DP connection
diagram 1)
GOT2000 Series Field Network Adapter Unit Instruction Manual
GOT
PROFIBUS DP
slave equipment
GOT
PROFIBUS DP
slave equipment
GOT
Max. distance
Option device
*1
*2
1200m
GT25-FNADP
7.2 System Configuration
Communication driver
PROFIBUS DP
Number of connectable
equipment
model
*3
7 - 3
7