18.4 Precautions
■1. RFID function setting on GT Designer3
Before connecting the RFID controller, set the RFID function and system data.
For details, refer to the following manual.
➠
GT Designer3 (GOT2000) Screen Design Manual
■2. Controller setting
(1) When using the external authentication
When using the external authentication on the RFID controller, set Channel No. 8 using the standard interface.
When connecting the RFID using Channels No. 5 to 7 of the extension interface, extension interface cannot be used.
For details on the external authentication, refer to the following manual.
➠
GT Designer3 (GOT2000) Screen Design Manual
(2) When requiring the power supply
When using the RFID controller, which requires the power supply from the GOT, set Channel No. 8 using the
standard interface.
With Channels No. 5 to 7 of the extension interface, the power cannot be supplied.
■3. Communication in multiple RFID readers/writers connection
When connecting multiple RFID readers/writers, some controllers may communicate with each RFID reader/writer.
For communicating the RFID controller with the each RFID reader/writer, set an interlock so that the RFID controller
does not communicate with RFID readers/writers until the executing communication is completed.
18.4 Precautions
18
18 - 7