18.4 Precautions

■1. RFID function setting on GT Designer3
Before connecting the RFID controller, set the RFID function and system data.
For details, refer to the following manual.
GT Designer3 (GOT2000) Screen Design Manual
■2. Controller setting
(1) When using the external authentication
When using the external authentication on the RFID controller, set Channel No. 8 using the standard interface.
When connecting the RFID using Channels No. 5 to 7 of the extension interface, extension interface cannot be used.
For details on the external authentication, refer to the following manual.
GT Designer3 (GOT2000) Screen Design Manual
(2) When requiring the power supply
When using the RFID controller, which requires the power supply from the GOT, set Channel No. 8 using the
standard interface.
With Channels No. 5 to 7 of the extension interface, the power cannot be supplied.
■3. Communication in multiple RFID readers/writers connection
When connecting multiple RFID readers/writers, some controllers may communicate with each RFID reader/writer.
For communicating the RFID controller with the each RFID reader/writer, set an interlock so that the RFID controller
does not communicate with RFID readers/writers until the executing communication is completed.
18.4 Precautions
18
18 - 7