■5. List of commands for formats 14, 15 (GOT-F900 series microcomputer connection)
Command
ASCII
Symbol
code
Batch read
0
30H
(w/out station No.)
Batch read
A
41H
(w/ station No.)
Batch write
1
31H
(w/out station No.)
Batch write
B
42H
(w/ station No.)
Multi-point write in bit
3
33H
units (w/out station No.)
Multi-point write in bit
D
44H
units (w/ station No.)
Fill command
4
34H
(w/out station No.)
Fill command
E
45H
(w/ station No.)
Set clock data
5
35H
(w/out station No.)
Set clock data
F
46H
(w/ station No.)
Read clock data
6
36H
(w/out station No.)
Read clock data
G
47H
(w/ station No.)
2 - 34
2.5 Message Formats
Command name
Reads bit devices in byte units.
Reads word devices in byte units.
Reads bit devices in byte units.
Reads word devices in byte units.
Writes to bit devices in byte units.
Writes to word devices in byte units.
Writes to bit devices in byte units.
Writes to word devices in byte units.
Writes bit patterns (bit ON/OFF, inversion, direct specification) in
1-point units (8 bits for 1 point) to a specified device.
Writes the same value to a range of specified devices.
Sets the clock data of the GOT.
Reads the clock data of the GOT.
Description
Max. number of points
processed
255bytes (2040 points)
255bytes (127 points)
255bytes (2040 points)
255bytes (127 points)
255bytes (2040 points)
255bytes (127 points)
255bytes (2040 points)
255bytes (127 points)
70bytes (560 points)