(a)
When sharing communication settings between multiple channel numbers
The table below shows the settings for the GS device.
GS device
GS570
Command selection
Function Code "01"
GS571
Specification for the max. number of coil
read times
Function Code "02"
GS572
Specification for the max. number of input
relay read times
Function Code "03"
GS573
Specification for the max. number of holding
register read times
Function Code "04"
GS574
Specification for the max. number of input
register read times
Function Code "0F"
GS575
Specification for the max. number of
multiple-coil write times
Function Code "10"
GS576
Specification for the max. number of
multiple-holding register write times
(b)
When configuring individual communication settings for specific channel numbers
The table below shows the settings for the GS device.
GS device
Ch1
Ch2
Ch3
GS590
GS597
GS604
GS591
GS598
GS605
GS592
GS599
GS606
GS593
GS600
GS607
GS594
GS601
GS608
GS595
GS602
GS609
GS596
GS603
GS610
Description
Bit0:0Using Function Code "0F"
1Not using Function Code "0F"
Bit1:0Using Function Code "10"
1Not using Function Code "10"
0:1000
1 to 2000: Specify the maximum number.
Other than above: 2000
0:1000
1 to 2000: Specify the maximum number.
Other than above: 2000
0:125
1 to 125: Specify the maximum number.
Other than above: 125
0:125
1 to 125: Specify the maximum number.
Other than above: 125
0:800
1 to 800: Specify the maximum number.
Other than above: 800
When Bit0 of GS570 is "1", the function code "0F" is not used, and therefore
the setting of GS575 will be disabled.
0:100
1 to 100: Specify the maximum number.
Other than above: 100
When Bit1 of GS570 is "1", the function code "10F" is not used, and
therefore the setting of GS576 will be disabled.
Description
Ch4
GS611
Command selection
Function Code "01"
GS612
Specification for the max. number of
coil read times
Function Code "02"
GS613
Specification for the max. number of
input relay read times
Function Code "03"
GS614
Specification for the max. number of
holding register read times
Function Code "04"
GS615
Specification for the max. number of
input register read times
Function Code "0F"
GS616
Specification for the max. number of
multiple-coil write times
Function Code "10"
GS617
Specification for the max. number of
multiple-holding register write times
Set value
Set value
Bit0:0Using Function Code "0F"
1Not using Function Code "0F"
Bit1:0Using Function Code "10"
1Not using Function Code "10"
0:1000
1 to 2000: Specify the maximum number.
Other than above: 2000
0:1000
1 to 2000: Specify the maximum number.
Other than above: 2000
0:125
1 to 125: Specify the maximum number.
Other than above: 125
0:125
1 to 125: Specify the maximum number.
Other than above: 125
0:800
1 to 800: Specify the maximum number.
Other than above: 800
When Bit0 of GS570 is "1", the function code "0F" is not
used, and therefore the setting of GS575 will be disabled.
0:100
1 to 100: Specify the maximum number.
Other than above: 100
When Bit1 of GS570 is "1", the function code "10F" is not
used, and therefore the setting of GS576 will be disabled.