2.5.2
List of commands
The following shows the list of commands available in each data format.
■1. List of commands for formats 1, 2 (GOT-A900 Series microcomputer connection)
Command
ASCII
Symbol
code
Batch read
RD
52H 44H
in word units
Batch write
WD
57H 44H
in word units
Random read
RR
52H 52H
in word units
Random write
RW
52H 57H
in word units
TR
54H 52H
Read clock data
TS
54H 53H
Set clock data
*1
■2. List of commands for formats 3 to 6 (A compatible 1C frame)
Command
ASCII
Symbol
code
BR
42H 52H
Batch read
JR
4AH 52H
in bit units
WR
57H 52H
Batch read
QR
51H 52H
in word units
BW
42H 57H
Batch write
JW
4AH 57H
in bit units
WW
57H 57H
Batch write
QW
51H 57H
in word units
BT
42H 54H
Test in bit units
JT
4AH 54H
(random write)
WT
57H 54H
Test in word units
QT
51H 54H
(random write)
*1
54H 52H
Read clock data
TR
*1
54H 53H
Set clock data
TS
*1
*2
2 - 32
2.5 Message Formats
Command name
Reads bit devices in 16-point units.
Reads word devices in 1-point units.
Writes to bit devices in 16-point units.
Writes to word devices in 1-point units.
Reads multiple different bit devices in 16-point units.
*1
Reads multiple different word devices in 1-point units.
Writes to multiple different word devices in 16-point units.
*1
Writes to multiple different word devices in 1-point units.
Reads the clock data of the GOT.
Sets the clock data of the GOT.
Mixed specification of bit devices and word devices is also possible.
Command name
Reads bit devices in 1-point units.
Reads bit devices in 16-point units.
Reads word devices in 1-point units.
Writes to bit devices in 1-point units.
Writes to bit devices in 16-point units.
Writes to word devices in 1-point units.
Writes to multiple different bit devices in 1-point units.
Writes to multiple different bit devices in 16-point units.
Writes to multiple different word devices in 1-point units.
Reads the clock data of the GOT.
Sets the clock data of the GOT.
This is a dedicated command of GOT for the microcomputer connection.
Specifies the address of bit devices in 16-point units. (Example: M0, M16, M32, and others)
Description
Description
*2
*2
*2
Max. number of points
processed
99 words(1584points)
99 points
99 words(1584points)
99 points
256 words(4096points)
256 points
128 words(2048points)
128 points
Max. number of points
processed
64 points
64 words (1024 points)
64 points
64 points
64 words (1024 points)
64 points
64 points
64 words (1024 points)
64 points

Hide quick links: