3.5.3
GOT Standard Ethernet Setting
The GOT can be connected to a different network by using the following interface.
• Standard Ethernet interface:
Set the [GOT IP Address] and [Subnet Mask] in the GOT built-in Ethernet interface.
• Extension Ethernet interface:
Set the [GOT Extension IP Address] and [Extension Subnet Mask] in the Ethernet interface for the Ethernet
communication module.
BootOS Version Z or higher is required to use the extension Ethernet Interface.
For details on writing the BootOS, refer to the following manual.
➠
The standard Ethernet interface and extension Ethernet interface use the same [Default Gateway].
Item
The GOT standard Ethernet settings
are applied on the GOT unit.
GOT IP Address
Select from GOT Setting List
Subnet Mask
Default Gateway
Peripheral S/W Communication Port
No.
Transparent Port No.
The GOT extension Ethernet
settings are applied on the GOT
*1
unit.
Enabling the extension Ethernet
*1
GOT Extension IP Address
*1
Extension Subnet Mask
*1
3 - 72
3.5 GOT Side Settings
GT Designer3 (GOT2000) Screen Design Manual
The standard Ethernet settings are applied on GOT.
Set the IP address of the Standard Ethernet interface.
(Default: 192.168.3.18)
Select the set GOT in the [GOT Setting List] dialog.
➠
GT Designer3 (GOT2000) Help
Set the subnet mask for the sub network. (Only for connection via router)
If the sub network is not used, the default value is set.
(Default: 255.255.255.0)
Set the router address of the default gateway where the GOT is
connected. (Only for connection via router)
(Default: 0.0.0.0)
Set the GOT port No. for the communication with the peripheral S/W.
(Default: 5015)
Set the GOT port No. for the transparent function.
(Default: 5014)
The extension Ethernet settings are applied on GOT.
Enable the extension Ethernet settings.
An error message will appear if all of the [Extension I/F Setting] in the [I/F
communication setting] dialog are used.
*1
Always set on of the [Extension I/F Setting] to [Not used].
➠
1.1.2 I/F communication setting
Set the IP address of the Extension Ethernet.
(Default: 192.168.5.22)
Set the subnet mask for the sub network. (Only for connection via router)
If the sub network is not used, the default value is set.
(Default:255.255.255.0)
For the microcomputer connection (Ethernet), the GOT2000 Series Ethernet communication unit (GT25-J71E71-100) is not
applicable. Use the GOT built-in standard Ethernet port.
Description
Range
-
0.0.0.0 to 255.255.255.255
-
0.0.0.0 to 255.255.255.255
0.0.0.0 to 255.255.255.255
1024 to 65534
(Except for 5011 to 5013, 49153 to 49170)
1024 to 65534
(Except for 5011 to 5013, 49153 to 49170)
-
-
0.0.0.0 to 255.255.255.255
0.0.0.0 to 255.255.255.255