6.6.7

Sensors and external sensor interface module (ATD4xxW)

6.6.7.1

Overview

The signals in the figure below are processed and generated via the internal signal logic of
SIDOOR ATD4xxW controllers. The system responses to the signals shown are described in
Section Drive functions (Page 35).
Image 6-26
Table 6- 33
Signal
DCOPS
LB
TestOUT
ESPE
SR
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
Sensor signals
Sensor signals
Meaning
Door Closed / Opened Position
Sensor
(Door Closed / Opened Position
Sensor)
Light barrier
(Light Barrier)
Function test signal
Electrosensitive protective equip-
ment
Pressure-sensitive edge
(Pressure-sensitive edge)
6.6 Connecting terminals and interfaces
Source
Signal can be transferred locally (terminal X6,
"Input1") and/or via the process image (see
Table 6-75 DCMD expansion bits (Page 207))
Signal is only contained in the process image
(see Table 6-75 DCMD expansion bits
(Page 207))
Signal is automatically output by the controller
via a digital relay output.
Relay module terminal X12 (reversing relay)
Fieldbus module terminal X100.1, X100.2
(closed relay)
Function-tested 0 active local signal (terminal
X6, "Input 1")
Function-tested 0 active local signal (terminal
X6, "Input 1")
Controllers
159