3-1-2. Paint Menu
The Paint menu is used for white and other paint adjustments items. To activate the Paint menu, first
display the TOP menu.
(Boxed items under "Settings" indicate the factory setting.)
Page
Ver.
Item
VIDEO
WHITE R/G/B
LEVEL
BLACK R/G/B/M
FLARE R/G/B
GAMMA R/G/B/M
FLARE
TEST
CLEAR
DETAIL1
DETAIL
LEVEL
LIMITTER
CRISPENING
LEVEL DEP
LEVEL DEP
TEST
CLEAR
DETAIL2
DETAIL
H/V RATIO
FREQUENCY
MIX RATIO
W.LIMITTER
B.LIMITTER
COMB
KNEE APRT.
TEST
CLEAR
BVP-550
Settings
Contents
–99 to 99 ([0])
Adjusts the R, G, B gain level.
–99 to 99 ([0])
Adjusts the R, G, B master black level.
–99 to 99 ([0])
Adjusts the R, G, B flare level.
–99 to 99 ([0])
Adjusts the R, G, B master gamma correction curve.
[ON], OFF
Turns the flare correction circuit on and off.
1, 2, [OFF]
Selects the test signal.
1
: Outputs the sawtooth waveform test signal
2
: Outputs 3-step waveform test signal
OFF : No test signal is output
Press MENU SEL
Sets all settings on the VIDEO LEVEL page to 0.
switch to execute.
(When you press MENU SEL switch, the "CLEAR" indication flashes.
Press MENU SEL switch again to execute; press CANCEL button to cancel.)
[ON], OFF
Turns the function on and off to improve resolution by adding the detail signal.
–99 to 99 ([0])
Adjusts the master level for the detail signal.
–99 to 99 ([0])
Adjusts the clipping level against the maximum detail level.
–99 to 99 ([0])
Adjusts the level at which the detail signal is crispened.
–99 to 99 ([0])
Adjusts the level to control the detail signal used at lower signal level.
[ON], OFF
Turns the level depend function on and off.
1, 2, [OFF]
Selects the test signal.
1
: Outputs the sawtooth waveform test signal
2
: Outputs 3-step waveform test signal
OFF : No test signal is output
Press MENU SEL
Sets all settings on the DETAIL 1 page to 0.
switch to execute.
(When you press MENU SEL switch, the "CLEAR" indication flashes.
Press MENU SEL switch again to execute; press CANCEL button to cancel.)
[ON], OFF
Turns the function on and off to improve resolution by adding detail signal.
–99 to 99 ([0])
Adjusts the mix ratio of H and V detail signal.
–99 to 99 ([0])
Adjusts the boost frequency for H detail signal.
–99 to 99 ([0])
Adjusts the mix ratio of H detail signal used before and after the gamma
compensation circuit.
–99 to 99 ([0])
Adjust the clipping level adainst the higher detail signal at the maximum level.
–99 to 99 ([0])
Adjusts the clippping level against the lower detail signal at the minimum level.
–99 to 99 ([0])
Sets the effect volume of the comb filter
99 (Causes less cross colors.) ↔ –99 (Yields clear pictures, but causes more
cross colors.)
* For a PAL model, this function has the effect on not every object but a specified object.
ON, [OFF]
Turns the knee aperture function on and off.
1, 2, [OFF]
Selects the test signal.
1
: Outputs the sawtooth waveform test signal
2
: Outputs 3-step waveform test signal
OFF : No test signal is output
Press MENU SEL
Sets all settings on the DETAIL2 page to 0.
switch to execute.
(When you press MENU SEL switch, the "CLEAR" indication flashes.
Press MENU SEL switch again to execute; press CANCEL button to cancel.)