Sony BVP-550 Maintenance Manual page 51

Digital 1000 series color video camera
Hide thumbs Also See for BVP-550:
Table of Contents

Advertisement

Page
Item
PRE KNEE/ZEBRA WHITE CLIP
WHITE CLIP
ZEBRA1 LEVEL,WIDE XXX ([XX])
ZEBRA2 LEVEL
Z.DISP
TEST
VTR/CCU
VTR R-Y
VTR B-Y
CCU Y SAMP
CCU R-Y SYNC
CCU B-Y SAMP
RGB OFFSET
TEST
CB
IRIS
LEVEL
APL RATIO
FILTER,WHT MEM [ON], OFF
OTHERS
NTSC ENC
ROTARY
OWN CALL
CENTER H POS
CENTER V POS
LENS VTR S/S
VF ? DISPLAY
BVP-550
BVP-550P
Settings
Contents
XXX ([XX])
Adjusts the white clip level.
[ON], OFF
Turns the white clip function on and off.
Sets the center value and range for the zebra 1 signal detection.
XXX ([XX])
Sets the detection value for the zebra 2 signal.
1,2, 1&2
Selects a zebra signal to be displayed on the viewfinder.
1: Zebra 1 signal
2: Zebra 2 signal
1&2: Both zebra 1 and 2 signals are displayed at the same time.
1, 2, [OFF]
Selects a TEST signal to be output in setting each item on the PREKNEE/
ZEBRA page.
1: Outputs the sawtooth test signal
2: Outputs the 3-step waveform test signal
OFF: No test signal is output
XXX ([XX])
Adjusts the R-Y color-difference signal level.
XXX ([XX])
Adjusts the B-Y color-difference signal level.
XXX ([XX])
Adjusts the level of the sample pulse to be mixed with the Y signal.
XXX ([XX])
Adjusts the level of the sync pulse to be mixed with the R-Y signal.
XXX ([XX])
Adjusts the level of the sample pulse to be mixed with the B-Y signal.
XXX ([XX])
Adjusts the G signal level.
1, 2, [OFF]
Selects a TEST signal to be output in setting each item on the VTR/CCU page.
1: Outputs the sawtooth test signal
2: Outputs the 3-step waveform test signal
OFF: No test signal is output
ON, [OFF]
Turns on and off the camera color-bar signal to be output in setting each
item on the VTR/CCU page.
-99 to 99 ([XX])
Adjusts the auto-iris level.
Sets the way the iris is automatically adjusted. -99 (PEAK) ↔ 99 (AVERAGE)
-99 to 99 ([0])
ON: A total of 8 settings of the white balance value can be saved in
conbination with the CC filter and WHITE BAL switch settings.
OFF: One white balance value can be saved for the WHITE BAL switch
setting A or B, for a total of 2 settings.
[WIDE], NRW
Sets the band width of the Q signal for the NTSC color encoder.
[STD], RVS
Selects the mode of MENU SEL switch (as turned counterclockwise when
viewed from the front.)
STD: Cursor moves downwards and a numeric value increases.
RVS: Cursor moves upwards and a numeric value decreases.
R, F&R , OFF
Selects whether one or two TALLY lamps are lit corresponding to the
CALL button of camera adaptor pressed, or not. Or selects which TALLY
lamp is lit when the CALL button is pressed.
(This setting is valid in connection with CCU. When the camera is used
alone, it is always set to OFF.)
R: Rear TALLY lamp is lit.
R&F: Rear and front TALLY lamps are lit.
OFF: No TALLY lamp is lit corresponding to the CALL button.
XXX ([XX])
Shifts horizontally the location of the center marker on the screen.
XXX ([XX])
Shifts vertically the location of the center marker on the screen.
TALK, [RET2]
Selects the mode of VTR S/S SW of the lens and camera.
TALK: VTR S/S SW of lens functions as INCOM TALK SW (momentary)
and that of the camra as RET2 SW.
RET2: VTR S/S SW of lens functions as RET2 SW and that of the camera
as INCOM TALK SW.
[ON], OFF
Turns on and off the indication of ? mark at the top-right of the VF screen with
the DISP switch set to ON when the self-diagnosis result is NG (no good)and
so on.
3-1. Setup Menu
3-13(E)