Va Mod Adjustment - Sony BVP-550 Maintenance Manual

Digital 1000 series color video camera
Hide thumbs Also See for BVP-550:
Table of Contents

Advertisement

4-4. Overall Electrical Alignment
4. Connect the oscilloscope to the TP54 (GND:TP53)/
Extension board extending VA-163.
Adjustment point : 1RV200 (C4)/VA-163
: B = 880 ±5 mV
Specifications
5. Connect the oscilloscope to the TP72 (GND:TP71)/
Extension board extending VA-163.
Specifications
: Adjust the iris control of the
lens.
A = 125 mV
6. Connect the oscilloscope to the TP52 (GND:TP51)/
Extension board extending VA-163.
Adjustment point : 1RV300 (D4)/VA-163
: B = 880 ±5 mV
Specifications
7. Connect the oscilloscope to the TP70 (GND:TP69)/
Extension board extending VA-163.
Specifications
: Adjust the iris control of the
lens.
A = 125 mV
8. Connect the oscilloscope to the TP50 (GND:TP49)/
Extension board extending VA-163.
Adjustment point : 1RV400 (F4)/VA-163
: B = 880 ±5 mV
Specifications
4
3
VA
TEST
R GAIN
CT200
RV200
R
G GAIN
CT300
R
RV300
B GAIN
CT400
B
RV400
VA-163 BOARD (COMPONENT SIDE)
4-32(E)
2
1
A
B
C
D
E
F
G

4-4-11. VA MOD Adjustment

Equipment : Waveform monitor
Test point : TEST OUT connector
Preparations:
Connect the waveform monitor to the TEST OUT connec-
tor.
GAIN switch (on the side panel) → L (0 dB)
Iris of the lens : CLOSE
RGB/ENC switch (on the side panel) → RGB
R/G/B switch (on the side panel) → R
Adjustment procedures:
1. VA MOD [R] Adjustment
MENU setting:
MENU
: Maintenance
PAGE
: White Shading (M2)
: H Saw [R] → 99
ITEM
Adjustment point:
MENU
: System config
PAGE
: PR/VA/TEST (S3)
ITEM
: VA MOD [R]
Specifications: Flatten the portion A.
Adjust so that the level at portion A
does not fluctuate even if the setting
value for H Saw [R] varies from 99
to –99.
(×5)
BVP-550
BVP-550P

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bvp-550p

Table of Contents