Skin Tone Adjustment - Sony BVP-550 Maintenance Manual

Digital 1000 series color video camera
Hide thumbs Also See for BVP-550:
Table of Contents

Advertisement

4-2. Adjustment for Installation of OHB
2. Make a selection of line at the center white portion of
the grayscale chart.
3. White Limitter Adjustment
Set the menu as follows, and set the clip level by
turning the MENU SEL switch.
MENU
: Paint
PAGE
: Detail 2 (P3)
ITEM
: W.Limitter
Specifications: Adjust the edges of portion (a) to
the desired clip level.
(Waveform Monitor)
4. Black Limitter Adjustment
Set the menu as follows, and set the clip level by
turning the MENU SEL switch.
MENU
: Paint
PAGE
: Detail 2 (P3)
ITEM
: B.Limitter
Specifications: Adjust the edges of portion (b) to
the desired clip level.
(Waveform Monitor)
4-18 (E)
Line Select

4-2-15. Skin Tone Adjustment

Note:
• Perform this adjustment on the customer's preferences, if
necessary.
Equipment : Color monitor, Viewfinder or Vectorscope
Preparations:
Connect the vectorscope to the TEST OUT connector.
Shoot a person's face.
Set the menu as follows.
MENU : Paint
PAGE
: Skin Detail (P4)
ITEM
: Skin Detail→On
Adjustment procedures:
1. Set the menu as follows.
MENU : Paint
PAGE
: Skin Detail (P4)
ITEM
: Gate→On
2. Set the menu as follows, and adjust the amount of the
skin detail signal to the desired level according to the
following menus by turning the MENU SEL switch.
MENU : Paint
PAGE
: Skin Detail (P4)
ITEM
: Phase: Hue
ITEM
: Saturation: Component in the saturation
direction
ITEM
: Width: Component in the hue direction
(The effective area of the skin detail signal appears in
a zebra pattern on the viewfinder screen. Set the
desired level.)
R-Y
phase
Width
Saturation
(Vector scope Monitor)
3. Set the menu as follows.
MENU : Paint
PAGE
: Skin Detail (P4)
ITEM
: Gate→Off
B-Y
BVP-550
BVP-550P

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bvp-550p

Table of Contents