3-1. Setup Menu
3-1-4. Reference Menu
3-1-5. Triming Menu
3-1-4. Reference Menu
The Reference menu stores the reference values used for automatic setup adjustment and the standard settings of the
switches as the reference files. And the menu can clear the current reference files. The Reference menu is not normally
accessible. To display this menu, switch setting of the AT-95 board is required. For details, refer to Section 1-3.
"Function of Internal Switches—AT-95 board". To activate the Reference menu, first display the TOP menu.
m
1. Executing the FILE STORE on the REFERENCE FILE page registers settings of items, which have been set through
the Paint, Maintenance and System config menus just before the file store, as the reference values.
2. When changed numbers of items are returned to the reference values stored as the reference files, recall the standard
file using an MSU/RCP or the setup menu.
Page
Ver.
Item
REFERENCE
FILE STORE
FILE
CLEAR FILE
p)
If the power is turned off without execution of the FILE STORE after clearing the file, the original setting is restored.
3-1-5. Triming Menu
The Triming menu stores the adjustment data in replacing parts as the triming files. And the menu can clear the current
adjustment values. The Triming menu is not normally accessible. To display this menu, switch setting of the AT-95 board
is required. For details, refer to Section 1-3. "Function of Internal Switches—AT-95 board". To activate the Triming
menu, first display the TOP menu.
n
Executing the FILE STORE on the TRIMING FILE page registers settings of items, which have been set through the
Maintenance and System config menus just before the file store, as the reference values.
Page
Ver.
Item
TRIMING
FILE STORE
FILE
CLEAR FILE
OHB FILE
FILE STORE
LENS FILE
1.10
LENS FILE
STORE
1.10
SELECT
CURRENT
LENS
1.10
RESET ALL
LENS
p)
If the power is turned off without execution of the FILE STORE after clearing the file, the original setting is restored.
3-12(E)
Settings
Contents
Press MENU SEL
Stores the adjustment value on each item as the reference value.
switch to execute.
Press MENU SEL
Clears the adjustment values stored as the reference files.
switch to execute.
(Temporarily clears the current reference files
Settings
Contents
Press MENU SEL
Stores the adjustment value on each item as the reference value.
switch to execute.
Press MENU SEL
Clears the adjustment values stored as the triming files.
switch to execute.
(Temporarily clears the current triming files
Press MENU SEL
Stores specific data for a CCD unit to be used as the OHB files.
switch to execute.
The standard values are stored at the factory.
(Stores the offset value, OHB matrix data and so on.)
Press MENU SEL
Stores specific data for a lens to be used as the lens files.
switch to execute.
The standard values are stored at the factory.
[0] to 49
Loads a lens data into the lens file selected at present by the LENS
FILE page of the Operation menu.
Press MENU SEL
Resets all of 16 lens files.
switch to execute.
(Example) No. : 1
← Lens stored number (0 to 49)
Lens : 27 : A14x8BERM ← Lens name
← Lens extender value
EX : 1.0