ANALOG CA (68P FEMALE)
*: In connection with CCU, **: In connection with VTR
No.
SIGNAL
1
UNREG GND
2
UNREG GND
3
VF UNREG GND
4
LENS UNREG GND
5
UNREG IN
6
UNREG IN
7
VF UNREG IN
8
LENS UNREG IN
9
R OUT (X)
10
B OUT (X)
11
VBS OUT (G)
12
Y OUT (X)
13
B-Y OUT (X)
14
NC
15
C OUT (X)
16
VBS GENLOCK IN (X)
17
RET VIDEO IN (G)
18
MONITOR VIDEO OUT (X)
19
BATTERY ALARM IN
20
NC
21
AUDIO CH1 CONT OUT
22
MIC 1 OUT (Y)
23
NC
24
SKIN TONE GATE OUT
25
TAPE REM IN
26
VTR SYNC OUT
27
RET EN OUT
28
PB REF IN
29
H CONT IN
30
ANALOG GND
31
DIGITAL HD OUT
32
COM CONT IN
33
IIC CLOCK OUT (CA)
34
IIC CLOCK OUT (ST)
BVP-550
BVP-550P
34
68
SPECIFICATIONS
GND for UNREG
GND for UNREG
GND for VF UNREG
GND for LENS UNREG
10.5 V to 17 V
10.5 V to 17 V
10.5 V to 17 V
10.5 V to 17 V
700 mVp-p ±2%, DC 0 ±200 mV, Zo = 75 Ω
700 mVp-p ±2%, DC 0 ±200 mV, Zo = 75 Ω
GND for VBS VIDEO
VS 1.0 Vp-p, Zo = 75 Ω
700 mVp-p, with sample 350 mV*
756 mVp-p (J)
700 mVp-p (UC)
**
525 mVp-p (CE)
No connection
SC for S connector
1.0 Vp-p ±6 dB
GND for RET VIDEO
VS 1.0 Vp-p, Zo = 75 Ω
Zi = 300 Ω *
Note 2
No connection
0 V (0 dB) to 7 V (–50 dB or less)
Zo ≤ 600 Ω, –60 dBu balanced
No connection
1.0 Vp-p
Note 4
*
+5.0 Vp-p Negative pulse, Zo ≤ 100 Ω
ENABLE; 0 V, DISABLE; +5 V or OPEN
PB; +4.5 V,
CAM; 0 V or OPEN
0 V to 5 V, Analog
3 Vp-p for Digital
5 Vp-p
5 Vp-p
5 Vp-p
1
35
No.
SIGNAL
35
UNREG GND
36
UNREG GND
37
VF UNREG GND
38
LENS UNREG GND
39
UNREG IN
40
UNREG IN
41
VF UNREG IN
42
LENS UNREG IN
43
G OUT (X)
44
R/G/B GND
45
VBS OUT (X)
46
R-Y OUT (X)
47
Y/R-Y/B-Y GND
48
NC
49
C OUT (G)
50
VBS GENLOCK IN (G)
51
RET VIDEO IN (X)
52
MONITOR VIDEO OUT (G)
53
VTR START/STOP OUT
54
NC
55
MIC 1 OUT (G)
56
MIC 1 OUT (X)
57
NC
58
NC
59
AUDIO LEVEL IN
60
NC
61
V RESET IN/CF OUT
62
REC TALLY IN
63
VTR SAVE OUT
64
GND
65
SD IN/OUT
66
COM DATA OUT
67
IIC DATA IN/OUT (CA)
68
IIC DATA IN/OUT (ST)
1-2. Connectors and Cables
(EXTERNAL VIEW)
SPECIFICATIONS
GND for UNREG
GND for UNREG
GND for VF UNREG
GND for LENS UNREG
10.5 V to 17 V
10.5 V to 17 V
10.5 V to 17 V
10.5 V to 17 V
700 mVp-p ±2%, DC 0 ±200 mV, Zo = 75 Ω
GND for R/G/B VIDEO
1.0 Vp-p ±10%, Zo = 75 Ω
700 mVp-p, with sync 350 mV*
756 mVp-p (J)
700 mVp-p (UC)
**
525 mVp-p (CE)
GND for Y/R-Y/B-Y
No connection
GND for C
GND for GENLOCK/H CONT IN
1.0 Vp-p, Zi = 1 kΩ
GND for MONITOR VIDEO
Zo ≤ 10 kΩ
No connection
GND for CAM MIC
Zo ≤ 600 Ω, –60 dBu balanced
No connection
No connection
Zi ≥ 1 kΩ (–15 dBu at 0 VU)
No connection
V Reset;0 V to +5 V, CF; 0 V to –5 V
ON; +5 V,
OFF; +2.5 V or 0 V,
Zi ≥ 20 kΩ *
Note 3
SAVE; +4.5 V, STANDBY; 0 V, Zo ≤ 10 kΩ
Serial data for camera control
5 Vp-p
5 Vp-p, 4700 Ω, Pull up
5 Vp-p, 4700 Ω, Pull up