When You Do Not Use The Forced Stop Deceleration Function - Mitsubishi Electric MR-J4 Instruction Manual

Servo amplifers mr-j4-_a_(-rj), mr-j4-03a6(-rj) melservo-j4
Hide thumbs Also See for MR-J4:
Table of Contents

Advertisement

3. SIGNALS AND WIRING
(2) When the forced stop deceleration function is not enabled
Servo motor speed
Base circuit
(Energy supply to
the servo motor)
Servo amplifier
display
MBR
(Electromagnetic
brake interlock)
ALM (Malfunction)

3.8.2 When you do not use the forced stop deceleration function

The operation status during an alarm is the same as section 3.8.1 (2).
0 r/min
ON
OFF
No alarm
ON
OFF
ON (no alarm)
OFF (alarm)
POINT
To disable the function, set "0 _ _ _" in [Pr. PA04].
Alarm occurrence
Braking by the dynamic brake
Alarm No.
Operation delay time of the electromagnetic brake
3 - 60
Dynamic brake
+ Braking by the electromagnetic brake

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j4-03a6

Table of Contents