Home Position Setting - Mitsubishi Electric MR-J4 Instruction Manual

Servo amplifers mr-j4-_a_(-rj), mr-j4-03a6(-rj) melservo-j4
Hide thumbs Also See for MR-J4:
Table of Contents

Advertisement

12. ABSOLUTE POSITION DETECTION SYSTEM

12.6.3 Home position setting

(1) Dog type home position return
Preset a home position return creep speed at which the machine will not be given impact.
On detection of a zero pulse, CR is turned from off to on. At the same time, the servo amplifier clears the
droop pulses, comes to a sudden stop, and stores the stop position into the non-volatile memory as the
home position absolute position data.
CR should be turned on after it has been confirmed that INP is on. If this condition is not satisfied, [AL.
96 Home position setting warning] will occur, but that warning will be reset automatically by making
home position return correctly.
The number of home position setting times is limited to 1,000,000 times.
Servo motor
DOG (Proximity dog)
INP (In-position)
CR (Home position setting)
ABSB0 (ABS transmission data bit 0)
ABSB1 (ABS transmission data bit 1)
ABSV
(Absolute position undetermined)
Control circuit power supply
ON
OFF
ON
OFF
ON
OFF
20 ms or longer
ON
OFF
ON
OFF
12 - 20
Proximity dog
20 ms or longer
Update

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j4-03a6

Table of Contents