5. PARAMETERS
No./symbol/
Setting
name
digit
PB04
Set the feed forward gain.
FFC
When the setting is 100%, the droop pulses during operation at constant speed are
nearly zero. When the super trace control is enabled, constant speed and uniform
Feed forward
acceleration/deceleration droop pulses will be almost 0. However, sudden
gain
acceleration/deceleration will increase the overshoot. As a guideline, when the feed
forward gain setting is 100%, set 1 s or more as the acceleration time constant up to
the rated speed.
Setting range: 0 to 100
PB06
Set the load to motor inertia ratio or load to motor mass ratio.
GD2
The setting of the parameter will be the automatic setting or manual setting
depending on the [Pr. PA08] setting. Refer to the following table for details. When
Load to motor
the parameter is automatic setting, the value will vary between 0.00 and 100.00.
inertia ratio/
load to motor
mass ratio
Setting range: 0.00 to 300.00
_ _ _ 0 (2 gain adjustment mode 1
(interpolation mode))
_ _ _ 1: (Auto tuning mode 1)
_ _ _ 2: (Auto tuning mode 2)
_ _ _ 3 (Manual mode)
_ _ _ 4: (2 gain adjustment mode 2)
PB07
Set the response gain up to the target position.
PG1
Increasing the setting value will also increase the response level to the position
command but will be liable to generate vibration and/or noise.
Model loop
gain
The setting of the parameter will be the automatic setting or manual setting
depending on the [Pr. PA08] setting. Refer to the following table for details.
Setting range: 1.0 to 2000.0
_ _ _ 0 (2 gain adjustment mode 1
(interpolation mode))
_ _ _ 1: (Auto tuning mode 1)
_ _ _ 2: (Auto tuning mode 2)
_ _ _ 3 (Manual mode)
_ _ _ 4: (2 gain adjustment mode 2)
PB08
Set the gain of the position loop.
PG2
Set this parameter to increase the position response to level load disturbance.
Position loop
Increasing the setting value will also increase the response level to the load
gain
disturbance but will be liable to generate vibration and/or noise.
The setting of the parameter will be the automatic setting or manual setting
depending on the [Pr. PA08] setting. Refer to the following table for details.
Setting range: 1.0 to 2000.0
_ _ _ 0 (2 gain adjustment mode 1
(interpolation mode))
_ _ _ 1: (Auto tuning mode 1)
_ _ _ 2: (Auto tuning mode 2)
_ _ _ 3 (Manual mode)
_ _ _ 4: (2 gain adjustment mode 2)
Function
Pr. PA08
Pr. PA08
Pr. PA08
5 - 26
This parameter
Automatic setting
Manual setting
This parameter
Manual setting
Automatic setting
Manual setting
This parameter
Automatic setting
Manual setting
Automatic setting
Control
Initial
mode
value
[unit]
P
S
T
0
[%]
7.00
[Multiplier]
15.0
[rad/s]
37.0
[rad/s]