6. NORMAL GAIN ADJUSTMENT
(c) One-touch tuning execution
Stop symbol
Error code
Initial screen
(d) If an error occur
Stop symbol
2 s interval
Error code
Pushing the "SET" button will switch to the initial screen.
Initial screen
(e) If an alarm occur
One-touch tuning in progress
Alarm display
The one-touch tuning mode can be stopped by pushing the "SET" button regardless of
displayed item.
2 s interval
The stop symbol and error code "C 000" (cancel during tuning) will be displayed by turns
with 2 s interval.
Pushing the "SET" button will switch to the initial screen.
If an error occurs during the one-touch tuning, the tuning will be forcibly terminated and the
stop symbol and error code from "C 001" to "C 00F" will be displayed by turns with 2 s
interval.
Check the error cause referring table 6.2 of (1) (d) of this section.